Method: |
Magnetic Flux is generated in the tube, and leakage from defect |
|
|
|
|
Sensitivity: |
Excellent to O.D. Good to fair on I.D. defects. |
|
|
|
|
Size Range: |
2” (50mm) diameter and up. |
|
|
|
|
Advantages: |
Fast, Dry. Moderately sensitive. |
|
|
|
|
Disadvantages: |
Spurious signals from welds and other magnetic anomalies. Poor |
|
|
|
|
Cost: |
Moderate. Some consumables. |
|
|
|
|
Operator Skill Level |
Moderate. |
|
|
|